Model
|
EAGLE
|
|
Measuring gas
|
Ex (HC)
|
O2
|
CO
|
H2S
|
Toxic gases |
|
Measuring range
|
0-100 %LEL
0-50.000 ppm
|
0-40 vol%
|
0-500 ppm
|
0-100 ppm
|
(table above)
|
|
Detection principle
|
Catalytic combustion
|
Galvanic cell
|
Electrochemical cell
|
Electrochemical cell
|
Electrochemical cell
|
|
Indication accuracy
|
Max ± 5 % of full scale
|
|
Sampling method
|
Long-life pump, sampling over 30m possible
|
|
Display
|
- 4x20 characters LCD readout with backlight.
- Displays readings & status of 4 channels simultaneously.
- Backlight automatic for alarms and by demand with adjustable time.
|
|
Alarm indication
|
Buzzer (85 dB at 30 cm), dual high intensity LED’s and flashing display.
|
|
Alarm set points
|
(1) Alarm ≥ 10% LEL (2) Alarm ≥ 50% LEL
Over range ≥ 100% LEL
|
(1) Alarm ≤ 19,5 vol.%
(2) Alarm ≥ 23,5 vol.%
Over range ≥ 40 vol.%
|
(1) Alarm ≥ 25 ppm (2) Alarm ≥ 50 ppm
TWA ≥ 30 ppm STEL ≥ 60 ppm
Over range ≥ 100 ppm
|
(1) Alarm ≥ 10 ppm
(2) Alarm ≥ 30 ppm
TWA ≥ 10 ppm STEL ≥ 15 ppm
Over range ≥ 100 ppm
|
(on demand) |
|
Alarm types
|
- 2 alarms per channel plus STEL and TWA alarms
- Alarm set points and levels fully adjustable
- Trouble alarm: sensor connection, low battery, circuit error, flow alarm
|
|
Features
|
- STEL, TWA and Peak hold
- Methane elimination: if Methane is an interference factor
- Up to 400 hours of data logging
- Auto calibration
- Low flow alarm shuts pump off to avoid damage to instrument
- Single gas calibration capability
- Security “Adjustment Lockout Switch”
- Confirmation Beep (silenceable)
|
|
Operating temperature and humidity
|
-10°C to +40°C 0-95 % RH (non-condensing) |
|
Response time
|
Most gases within 30s (T90)
|
|
Operating time
|
Approx. 30 hours with Alkaline batteries, approx. 18 hours with Ni-Cd battery pack Continuous operation with power pack |
|
Power source
|
4x size D batteries (Alkaline or NiCd), optional power pack
|
|
Safety Rating
|
Intrinsically safe, Class 1, Division 1, Groups A, B, C and D CSA / NTRL & UL Classified (CO2 not included)
|
|
Housing
|
- Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-polyester blend
- Can operate in rain or set into 2,5’’ of water without damage.
- Ergonomically balanced with rugged top mounted handle.
|
|
Dimensions and weight
|
Approx. 270 x 150 x 180 mm, approx. 2,3 kg
|
|
Accessories
|
Standard: Shoulder strap, alkaline batteries, hydrophobic probe with 1.5 m hose, operation manual (for special toxic gas versions a shorter teflon hose without probe is used)
Optional: Data logging, remote alarm, Ni-Cd battery pack, battery charger, power pack, calibration gas, extra loud buzzer, extension probes, dilution fitting (50/50), large internal hydrophobic filter
|