DC2000

Stand Alone Calibration Stations

 

Aktuelles Datenblatt


DC-2001-2003-2009

DC-2000

The single module calibration stations for the GX-2009, GX-2003, and GX-2001 portable gas monitors are stand alone stations that can calibrate, bump test, charge, and archive data without the need of a computer to operate.
The stations feature 4 operating modes, which include:

  • Bump test only
  • %volume methane bump/calibration (GX-2003)
  • Calibration only
  • Bump with automatic calibration (if bump test fails)


Each module has user adjustable test times and tolerances. Therefore you can customize the system to meet your service requirements.
The stations are capable of storing up to 200 bump test or calibration records in their internal memory. After downloading the data the easy to use software allows to view, print, and export calibration & bump test records. Additionally, you can manage instrument records by serial #, user ID, or location ID.

Other features include:

  • Single button calibration and / or bump test: quick and easy performance verification
  • Charge instrument: no need for additional hardware



Features:

  • Stand alone system, no need for additional hardware
  • Single button calibration and / or bump test
  • User adjustable bump test times and tolerances
  • Automatic quick charge < 90 minutes
  • Easy to use software: manage records for storage,
  • data analysis or reference purpose
  • Download data any time or place with USB flash drive

Model

DC-2000_2001

DC-2000_2003

DC-2000_2009

Applicable Instrument

GX-2001

GX-2003

GX-2009

Input Power

AC100-240V, 50/60 Hz

Operating Temp. & Humidity

-10°C to +40°C; 0 to 80% RH, non-condensing

Operating Modes

• Bump test only
• % volume methane bump / calibration
• Calibration only
• Bump with automatic calibration (if bump fails)

Memory Capacity

64 KB, expandable with USB flash drive (64 MB flash drive stores up to 200.000 records)

Maximum Record Size

256 bytes

Maximum Number of
Records Saved

200 (internal memory, expandable with USB flash drive)

Power Requirements

115/230 VAC, 50/60Hz

PC-Software

Windows Vista, and XP compatible software, operates on any Pentium II or higher PC

Standard Accessories

AC Power Cord, Single Module Data Viewer Software, Inlet Air Filter, Instruction Manual

Specifications subject to change without notice.