SD-1

Smart Transmitter / Gas Detector

 

Aktuelles Datenblatt



SD-1

Our new SD-1 line of smart transmitters feature state-of-the-art gas detectors with durable flameproof enclosure, best operability and maximum safety, especially in hydrogen/acethylene atmospheres.
A simple magnetic control key is placed over clear marked positions on the surface plate to test and adjust the instrument without opening the transmitter in situations with danger of explosion. This “single-man-calibration” is already in use and appreciated with other RKI gas detectors for easy maintenance.

The built-in microprocessor features a self diagnosis functions and automatic zero setting to minimize maintenance work and costs compared to other detectors.
Dual alarm contacts or trouble alarm contact are provided for activation of external buzzer or alarm light. Powered by 24VDC, the unit has a 4-20mA output for communication to outside controllers, for external readouts or alarming devices.

Features

  • For combustible gases
  • Longlife RKI sensors
  • Dual alarm contacts (relais)
  • 4-20mA linear output
  • Self diagnosis + Single-Man-Calibration
  • Flameproof enclosure Exd II CT5, IP65
  • ATEX approved

SD-1 Outer Dimensions

 

JB-2 Translator (optional)

Measuring Gas

Formula

LEL

Resolution

Methane

CH4

5,0 Vol.%

0,5% LEL

Ethylene

C2H4

2,7 Vol.%

0,5% LEL

Ethane

C2H6

3,0 Vol.%

0,5% LEL

Propane

C3H8

2,0 Vol.%

0,5% LEL

Iso-Butane

i-C4H10

1,8 Vol.%

0,5% LEL

n-Hexane

n-C6H14

1,2 Vol.%

0,5% LEL

IPA

C3H8O

1,2 Vol.%

0,5% LEL

Toluene

C7H8

1,2 Vol.%

0,5% LEL

MEK

C4H8O

1,8 Vol.%

0,5% LEL

Ethanol

C2H5OH

3,3 Vol.%

0,5% LEL

 

Model

SD-1

Sampling method

Diffusion sampling

Detection principle

Catalytic combustion

Measuring gas

Combustible gases (see table above), please specify when ordering

Measuring range / increments

0~100%LEL / 0.1%LEL per digit

Resolution

±5% of full scale

Alarm delay time

30s (T60)

Alarm level and contact rating

1st alarm 25% LEL, 2nd alarm 50% LEL (standard), 30VDC 0.5A or 250VAC 0.5A

Output

Gas alarm (standard) or trouble alarm (option): normally open

Specification: 4-20 mA (300Ω)

Self diagnosis function

LED (yellow): system failure, communication error, short, EEPROM error

Ingress class

IP65

Certifications

ATEX (pending), CE

Explosion proof

Power supply

DC24V+/-10 % (consumed power 3W max.)

Applicable cable and
signal transmission

CVVS 3-core (power supply + 4-20 mA)

MAX 1.25km with 1.25sq cable, MAX 2.0km with 2.0sq cable

Operating conditions

-20°C ~ +53°C, 0~95% RH, non-condensing

Dimensions and weight

Approx. 148 (W) x 161 (H) x 88 (D) mm, 2.0 kg

Specifications subject to change without notice.