RM-TC4

Gas Detection Control Unit for

4 Transmitters / Gas Sensors

 

Aktuelles Datenblatt

RM-TC4

The RM-TC4 is a compact and easy to use device for up to four transmitters.
Thus it is perfectly suited for limited frames of measurement tasks, for which a secure warning of danger and a  minimum expenditure likewise is utmost important.
You are free to choose between 4 different types: RM-TC4X

W - Wall mounted housing
R - 19‘‘ Rack control panel
S - Control panel
H - DIN-Rail




 

Features

 

  • Gas Detection Control Unit for measurement of flammable and/or toxic gases as well as oxygen
  • Graphic display for indication of measuring values
  • 4 digital inputs (potential-free), 3 adjustable alarm levels per channel
  • Adjustable relays for individual signaling
  • 4 analogue outputs (Option): 4-20mA / 0-5V / 0-10V

 

Model

RM-TC4W

RM-TC4R

RM-TC4S

RM-TC4H

Number of Transmitters

1 to 4

Signal Processing

Microcontroller with A/D-Converter

Alarm / Fault / Indication

  • Backlighted graphic display for indication of measuring values
  • 12 (3x4) red LEDs for alarm indication
  • 4 yellow LEDs for indication of channel fault
  • 4 green LEDs for indication of channel operation
  • 1 green LED for indication of operation
  • 1 yellow LED for indication of main unit malfunction

Alarm Levels

3 freely adjustable alarm levels per channel, one of them is latching (Alarm 2)

Relays

  • 12 potential-free change-over contacts 230 V / 5 A (Alarm 1 to 3 and communication fault)

Additional Functions

  • 4 digital inputs, potential-free
  • Service function
  • Horn reset
  • RS 232/485-interface for configuration and maintenance
  • 4 analogue outputs (option): 4-29 mA / 0-5V / 0-10V

Operation Temperature

-10 °C to +40 °C

Installation

Wall mounted housing

DIN-Rail

19’’-Rack control panel

Control panel

Dimensions

194 x 245 x 120 mm

173 x 245 x 120 mm

194 x 245 x 120 mm

194 x 245 x 130 mm

Material

Housing ABS

Enclosure Rating

IP 54 (19’’: IP20)

Cable Gland

1 pc. M20 x 1,5 (diameter of cable 7-13 mm), 10 pcs. M16 x 1,5 (diameter of cable 5-10 mm)

Storage Temperature

-25 °C to +60°C

Power Supply

230 V (85…264 V AC, 47…440 Hz or 120…340 V DC) or 24 V DC alternatively

Power Consumption

Max. 0,2 A / 45 W (230 V*), 2 A / 45 W (24 V DC*)

EC-Directives

II (3)G
94/9/EC (ATEX), 89/336/EEC (EMC), 73/23/EEC (LVD)

Measuring Function

Designed according to:

  • EN 61779-1 to EN 61779-4
  • EN 45544-1 to EN 45544-3
  • EN 50104

Specifications subject to change.

*) please specify when ordering